Operate

SIEM forwarding

Necio can send every graded result to your SIEM or log platform as a structured JSON event, so findings from scheduled scans land next to the rest of your security telemetry. See what a compliance dashboard built from these events looks like.

Supported destinations

DestinationWhat you'll need
Splunk HECThe HEC endpoint URL and a token.
Datadog LogsThe logs intake URL for your site (US or EU) and an API key.
Microsoft Sentinel / Log AnalyticsThe workspace ID and shared key. Events land in the custom table necio_scan_results_CL.
Elastic Cloud (Bulk API)The _bulk endpoint URL and a base64-encoded id:secret API key.
Sumo LogicAn HTTP Source URL. The token is part of the URL.
New Relic LogsThe Log API URL (US or EU) and an API key.
Grafana LokiThe push API URL and a bearer token, for Grafana Cloud or self-hosted Loki.
SolarWinds Observability / PapertrailThe collector URL for your region and a token.
AWS CloudWatch LogsThe region, an existing log group and log stream, and an access key allowed logs:PutLogEvents on that stream.
Custom HTTPSAny HTTPS endpoint that accepts JSON with a bearer token.
SyslogA host and port, over UDP, TCP or TLS.

Azure Event Hub can be added as a second destination.

Set it up

  1. Open Settings and select SIEM Integration.
  2. Turn on Enable SIEM Logging and choose the protocol. For HTTPS, choose the vendor.
  3. Enter the endpoint and credentials.
  4. Select Test Connection. After it succeeds, select Save SIEM Settings.
  5. Optionally choose extra payload fields, or add Azure Event Hub as a second destination.

A successful Test Connection proves the destination accepts events. Run one real scan and check the event in your SIEM before you build alerts on it.

What gets sent

Necio sends one JSON event per graded result, and also forwards confirmed behavioral drift and Maestro campaign findings. To keep connection tests out of your finding counts, filter on sourcetype:

  • Scan results: source is necio-grader and sourcetype is necio:scan_results.
  • Test Connection events: sourcetype is necio:connection_test.

Each result event carries the scan and prompt identifiers, the pass or fail grade and severity, the OWASP risk codes and names (including secondary risks) with mapped NIST control IDs, the accuracy verdict, the grading model and the target's host. By default it also includes the IP address recorded when the scan was authorized; you can turn that off. Optional fields such as token counts, cost and duration are chosen in the SIEM settings.

Delivery health

Delivery failures appear in SIEM Settings, in Activity & Alerts, in email alerts and in the affected scan reports. Necio records each failure and recovery. Recovery means a later delivery succeeded; it doesn't confirm that an earlier failed event arrived, so check the destination for gaps.

How SIEM credentials are stored

Saved tokens and keys are encrypted at rest with AES-256-GCM and are never shown again after you save them. To change one, enter a new value.

Questions

What happens if my SIEM delivery fails?

Check SIEM Settings, Activity & Alerts and the affected scan report for the error. Fix the endpoint, credentials or network access, then select Test Connection. Necio records failures and recoveries and tries to email you. A later successful delivery does not by itself confirm that an earlier failed event arrived, so check the destination for missing events.

How do I keep connection tests out of my finding counts?

Filter on sourcetype. Real scan results use necio:scan_results, and Test Connection events use necio:connection_test.

Try it on your own app